{"created":"2023-05-15T11:43:13.712548+00:00","id":2864,"links":{},"metadata":{"_buckets":{"deposit":"649a49eb-7f71-4072-bea7-d0b424bd74d9"},"_deposit":{"created_by":1,"id":"2864","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2864"},"status":"published"},"_oai":{"id":"oai:kanagawa-u.repo.nii.ac.jp:00002864","sets":["237:238:239"]},"author_link":["5526","5527"],"item_7_alternative_title_20":{"attribute_name":"その他の言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"EVALUATION OF EARTHQUAKE RESISTANCE ABILITY FOR BASE ISOLATED BUILDINGS WITH INITIAL DEFORMATION BY DRY SHRINKAGE"}]},"item_7_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-04-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"51","bibliographicPageStart":"45","bibliographicVolumeNumber":"554","bibliographic_titles":[{"bibliographic_title":"日本建築学会構造系論文集"}]}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Shortening of R/C members caused by dry shrinkage for a base isolated building deforms a base-isolate-equipment. The deformation varies with its position. Usually, the largest value is at the edge of a building plan. The varied initial deformation leads to torsional vibration for the building. This paper examines this torsional vibration parametrically by 3-D dynamic analysis using the models of bilinear hysteresis systems for the vibration isolation materials. The results show that the initial deformation does not have an effect on the seismic ability of base isolated buildings for severe earthquakes. However, it leads to leave residual deformation after not only severe earthquakes but alsomoderate ones.","subitem_description_type":"Abstract"}]},"item_7_description_40":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_7_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Journal of structural and construction engineering. Transactions of AIJ (554), 45-51, 20020430 Architectural,Institute of Japan","subitem_description_type":"Other"},{"subitem_description":"カテゴリーⅢ","subitem_description_type":"Other"},{"subitem_description":"rights:日本建築学会 rights: 本文データは学協会の許諾に基づきCiNiiから複製したものである relation: isVersionOf: http://ci.nii.ac.jp/naid/110004081895","subitem_description_type":"Other"}]},"item_7_description_6":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"日本建築学会構造系論文集 ","subitem_description_type":"Other"}]},"item_7_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会"}]},"item_7_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1340-4202","subitem_source_identifier_type":"ISSN"}]},"item_7_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"島崎, 和司"}],"nameIdentifiers":[{"nameIdentifier":"5526","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shimazaki, Kazushi"}],"nameIdentifiers":[{"nameIdentifier":"5527","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-11-16"}],"displaytype":"detail","filename":"A-03.pdf","filesize":[{"value":"640.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"A-03.pdf","url":"https://kanagawa-u.repo.nii.ac.jp/record/2864/files/A-03.pdf"},"version_id":"43495937-2621-4248-a6da-b3134c0d79d5"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-11-16"}],"displaytype":"detail","filename":"P-03.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"P-03.pdf","url":"https://kanagawa-u.repo.nii.ac.jp/record/2864/files/P-03.pdf"},"version_id":"53234b60-8075-4386-b8b9-4386162dcc39"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Base isolated building","subitem_subject_scheme":"Other"},{"subitem_subject":"Dryshrinkage","subitem_subject_scheme":"Other"},{"subitem_subject":"Earthquake Resistant Design","subitem_subject_scheme":"Other"},{"subitem_subject":"Torsional vibration","subitem_subject_scheme":"Other"},{"subitem_subject":"residual deformation","subitem_subject_scheme":"Other"},{"subitem_subject":"免震構造","subitem_subject_scheme":"Other"},{"subitem_subject":"乾燥収縮","subitem_subject_scheme":"Other"},{"subitem_subject":"耐震設計","subitem_subject_scheme":"Other"},{"subitem_subject":"捩れ応答","subitem_subject_scheme":"Other"},{"subitem_subject":"残留変形","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"乾燥収縮により初期変形を受けた免震建物(LRB)の耐震性能の評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"乾燥収縮により初期変形を受けた免震建物(LRB)の耐震性能の評価"}]},"item_type_id":"7","owner":"1","path":["239"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-04-02"},"publish_date":"2010-04-02","publish_status":"0","recid":"2864","relation_version_is_last":true,"title":["乾燥収縮により初期変形を受けた免震建物(LRB)の耐震性能の評価"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T16:36:32.886596+00:00"}